Posted on: September 12, 2020 Posted by: admin Comments: 0

Click here to purchase
This Technical Report contains a recommendation on how to deal with statistics of radio interference complaints. Furthermore it describes the calculation of limits for disturbance field strength and voltage for the measurement on a test site based on models for the distribution of disturbances by radiated and conducted coupling. This second edition of CISPR 16-4-4 contains two thoroughly updated Clauses 4 and 5, compared with its first edition. It also contains, in its new Annex A, values of the classical CISPR mains decoupling factor which were determined by measurements in real low-voltage AC mains grids in the 1960s.respectively.

Product Details

Edition:
2.0
Published:
07/16/2007
Number of Pages:
61